Ground Floor – Internal Condensation
LOOSENING OF PVC FLOOR COVERING OF SPORTS PAVILION

ASSESSMENT AND MEASUREMENTS


When the floor configuration was analysed, it was found that the covering was glued directly onto the concrete support layer. This was a ground floor consisting of a gravel box, concrete support layer and glued PVC covering.
A dry carotage was performed on the support layer of the covering and the moisture content determined. The concrete was found to have a higher moisture content at the surface than deeper down.
The following measurements were taken in order to characterise the hygrothermal conditions:

      - Relative humidity at the glue joins of the covering;
      - Temperature at the various interfaces of the ground floor;
      - Indoor temperature and relative atmospheric moisture content.
 

        

KEYWORDS: 

Ground Floor, PVC Covering, Loosening of Covering, Internal Condensation, Vapour Barrier

AUTHORS: Vasco P. de Freitas / Marília Sousa      CHECKED BY: Fernando Henriques

 CREDITS online users 2 | last updated 30 april 09 
 
01. Pitched roof 02. Flat roof - Inaccessible 03. Flat roof - Accessible 04. Roof garden 05. External wall 06. Basement wall 07. Internal wall 08. Ground floor 09. Floor 10. Floor over exterior space 11. Doors and windows 12. Verge 13. Joint 14. Skylight 15. Balcony 16. Plant stand 17. Terrace parapet