Pathologies in ...







 

001

   

Ground Floor – Internal Condensation
LOOSENING OF PVC FLOOR COVERING OF SPORTS PAVILION

RECOMMENDATIONS


Correction of the pathology would involve the following steps (A):

      - Removal of the PVC covering;
      - Pricking-up of the support layer for around 0.06 m;
      - Regularization of the support;
      - Application of a vapour barrier with permeance - Wp less than
        2x10¹²kg/(m².s.Pa);
      - Placement of a polyethylene protection film;
      - Execution of a small slab of reinforced concrete 0.05m thick;
      - Gluing of the PVC covering.

Alternatively, the PVC covering could be replaced by a non-water sensitive covering and fixation system (B).

    

KEYWORDS: 

Ground Floor, PVC Covering, Loosening of Covering, Internal Condensation, Vapour Barrier

AUTHORS: Vasco P. de Freitas / Marília Sousa      CHECKED BY: Fernando Henriques

 CREDITS online users 1 | last updated 30 april 09 
 
01. Pitched roof 02. Flat roof - Inaccessible 03. Flat roof - Accessible 04. Roof garden 05. External wall 06. Basement wall 07. Internal wall 08. Ground floor 09. Floor 10. Floor over exterior space 11. Doors and windows 12. Verge 13. Joint 14. Skylight 15. Balcony 16. Plant stand 17. Terrace parapet